ASW-WP Installation Guide
RS232 and TCP/IP Commands
RS232 Settings: 9600 baud, 8 Data bits, 1 Stop bit, Parity = None
<CR> = Carriage return (Hex 0D)
<LF> = Line Feed (Hex 0A)
<SP> = Space (Hex 20)
*NOTE: You must turn Display Control OFF in order to gain control of the ASW-WP via RS232 –
please send the “Display Control OFF” command first! (See page 16)
System commands
This response indicates video
present on HDMI input
HDMI 0! <CR><LF>
This response indicates NO video
present on HDMI input
This response indicates video
present on VGA input
VGA 0! <CR><LF>
This response indicates NO video
Enter low-power mode (will disable
RS232 communications until
physical action wakes up ASW-WP)
No response – ASW-WP will power
cycle
Get HDCP Compliance status