Intelix FLX-44 Bedienungsanleitung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
FLX-44 Installaon Guide
14
Connect RS232 Control
In addion to tradional RS232 control, the FLX-44 has an advanced RS232 control mechanism which allows RS232
tunneling and roung through the HDBaseT output port to control remote devices. Intelix recommends using the
DIGI-HD60C-R for installaons which require RS232 extension.
See page 27 for all available control commands for the FLX-44.
Matrix Control via RS232
Remote RS232 Control via Tunneling
The RS232 control port requires a standard straight-through serial cable for operaon. The default sengs for the
RS232 port are:
9600 baud
8 Data Bits
1 Stop Bit
Parity = none
Connect a standard straight-through serial cable with DE9 connector
between the RS232 port on the FLX-44 and the controller.
Discrete remote control of remote display devices is possible by connecng an RS232 output of a control system
to the 3-pole terminal block on the output of the matrix. A compable HDBaseT with control receiver is required
to pass the control signals to the display devices.
To use the RS232 extension capabilies of the FLX-44, connect the TX, ground, and RX control signal wires to the
removable 3-pole terminal block. Consult the manual of the control device(s) to determine which pins the TX/RX
signals are carried on. Be sure to always connect TX to RX and RX to TX.
Tx
Rx
RXD
GND
TXD
FLX-44Controller
Rx
Tx
TXD
GND
RXD
DIGI-HD60C-R Display
Seitenansicht 13